Share:

BGV 385 ST

Balance range three-phase open generator, operating in automatic mode, manual mode, signal mode, or test mode. The most balanced energy for emergency applications.

Power (PRP / ESP):

355 / 386 kVA (284 / 309 kW)

VERSION:

Open

VOLTAGE:

400/230V

EMISSIONS LEVEL: EU Stage II

CE DECLARATION OF CONFORMITY

Data sheet

BGV 385 ST

BGV 385 ST

BGV 385 ST

BGV 385 ST

BGV 385 ST

BGV 385 ST

PRODUCT DETAILS

  • General information

    VERSION

    Open

    Fuel

    Diesel

    Voltage

    400/230V

    RPM

    1500

    Number of phases

    3

  • Size and weight

    L (mm)

    3400

    W (mm)

    1550

    H (mm)

    2233

    Weight (Kg)

    3350

  • Engine

    Engine make and model

    VOLVO TAD1342GE-B

    Type of regulation

    Electronic

    Refrigeration

    Water-cooled

    Emissions

    EU Stage II

    Consumption 50%

    35,9 l/h

    Consumption 75%

    52,2 l/h

    Consumption 100% PRP

    69,3 l/h

    Consumption 100% ESP

    76,5 l/h

  • Tank and autonomy

    Tank size (l)

    820 l

    Autonomy 50% PRP

    22,8 h

    Autonomy 75% PRP

    15,7 h

    Autonomy 100% PRP

    11,8 h

    Autonomy 100% ESP

    10,7 h

  • Alternator

    Alternator make and model

    STAMFORD S4L1D-E

    Type of alternator regulation

    AS440

  • Circuit breaker

    Switch model

    Chint 630A 4P

    Amps ESP (A)

    557,1

  • Control card

    Make and model

    DSE 7320 MKII

  • Downloadable documents
  • BGV 385 ST

    BGV 385 ST

    Range Emergency Balance

    | 50Hz

    Do you need an ATS for your installation?

    CONTACTORS TRANSFER SWITCHES

    Dagartech contactores

    Switching panels between mains and genset with Schneider Electric contactors and enclosure from the same manufacturer. With mechanical and electrical interlocking and switching management from the control panel. They have an optional mains failure detector.

    REMOTELY OPERATED MOTORISED TRANSFER SWITCH (RTS)

    Dagartech contactores

    Transfer switches with remote-operated 4-pole fully visible break. They allow in-load transfer of two three-phase sources via remote-voltage-free contacts, from an external automatic controller, using pulse logic or a switch.

    They are designed for use in low-voltage power systems where a brief interruption of load power during transfer is acceptable.

    What sectors is this generator optimal for?

    1111

    Generator sets for diverse industrial applications, as a main source of power supply or for emergency operation.

    See case

    Industry

    740

    Industry

    1419

    Power failure equipment with high attenuation elements offer reliable and silent service for housing estates and housing stock.

    See case

    Residential

    737

    Residential

    1108

    Generator sets that are ideal for emergency use in various public spaces, such as shopping centres, town halls and sports facilities.

    See case

    Equipment

    744

    Equipment

    903

    Generator sets for diverse industrial applications, as a main source of power supply or for emergency contexts.

    See case

    Agriculture and livestock

    734

    Agriculture and livestock

    1295

    From distribution centres to loading platforms. We ensure your uninterrupted flow with reliable and customised generator sets.

    See case

    Logistics

    1177

    Logistics