Share:

DGP 200 ST

Industrial range three-phase open generator, operating in automatic mode, manual mode, signal mode, or test mode. A commitment to quality energy.

Power (PRP / ESP):

184 / 204 kVA (147 / 163 kW)

VERSION:

Open

VOLTAGE:

400/230V

EMISSIONS LEVEL: EU Stage 0

CE DECLARATION OF CONFORMITY

Data sheet

DGP 200 ST

DGP 200 ST

DGP 200 ST

DGP 200 ST

DGP 200 ST

DGP 200 ST

PRODUCT DETAILS

  • General information

    VERSION

    Open

    Fuel

    Diesel

    Voltage

    400/230V

    RPM

    1500

    Number of phases

    3

  • Size and weight

    L (mm)

    2600

    W (mm)

    1000

    H (mm)

    1900

    Weight (Kg)

    1700

  • Engine

    Engine make and model

    PERKINS 1106A-70TAG3

    Type of regulation

    Mechanical

    Refrigeration

    Water-cooled

    Emissions

    EU Stage 0

    Consumption 50%

    20,1 l/h

    Consumption 75%

    31,8 l/h

    Consumption 100% PRP

    41,6 l/h

    Consumption 100% ESP

    44,6 l/h

  • Tank and autonomy

    Tank size (l)

    430 l

    Autonomy 50% PRP

    21,4 h

    Autonomy 75% PRP

    13,5 h

    Autonomy 100% PRP

    10,3 h

    Autonomy 100% ESP

    9,6 h

  • Alternator

    Alternator make and model

    STAMFORD UCI274H

    Type of alternator regulation

    AS440

  • Circuit breaker

    Switch model

    Schneider EasyPact 400A 4P

    Amps ESP (A)

    294,4

  • Control card

    Make and model

    DSE 6020 MKII

  • Downloadable documents
  • DGP 200 ST

    DGP 200 ST

    Range Industrial

    | 50Hz

    Do you need an ATS for your installation?

    CONTACTORS TRANSFER SWITCHES

    Dagartech contactores

    Switching panels between mains and genset with Schneider Electric contactors and enclosure from the same manufacturer. With mechanical and electrical interlocking and switching management from the control panel. They have an optional mains failure detector.

    REMOTELY OPERATED MOTORISED TRANSFER SWITCH (RTS)

    Dagartech contactores

    Transfer switches with remote-operated 4-pole fully visible break. They allow in-load transfer of two three-phase sources via remote-voltage-free contacts, from an external automatic controller, using pulse logic or a switch.

    They are designed for use in low-voltage power systems where a brief interruption of load power during transfer is acceptable.

    What sectors is this generator optimal for?

    1111

    Generator sets for diverse industrial applications, as a main source of power supply or for emergency operation.

    See case

    Industry

    740

    Industry

    1112

    Aviation, rail, sea or telecommunications are some of the most prominent destinations for these generator sets.

    See case

    Infrastructures

    741

    Infrastructures

    1109

    Generator sets for when failing is not allowed. With fail-safe components and a high level of standard equipment.

    See case

    Hospital

    738

    Hospital

    1419

    Power failure equipment with high attenuation elements offer reliable and silent service for housing estates and housing stock.

    See case

    Residential

    737

    Residential

    1295

    From distribution centres to loading platforms. We ensure your uninterrupted flow with reliable and customised generator sets.

    See case

    Logistics

    1177

    Logistics