Share:

DGV 825 ME

High-power, open three-phase generator, operating in automatic mode, manual mode, signal mode, or test mode. Limitless stellar energy, pure power.

Power (PRP / ESP):

750 / 825 kVA (600 / 660 kW)

VERSION:

Open

VOLTAGE:

400/230V

EMISSIONS LEVEL: EU Stage II

CE DECLARATION OF CONFORMITY

Data sheet

DGV 825 ME

DGV 825 ME

DGV 825 ME

DGV 825 ME

DGV 825 ME

DGV 825 ME

PRODUCT DETAILS

  • General information

    VERSION

    Open

    Fuel

    Diesel

    Voltage

    400/230V

    RPM

    1500

    Number of phases

    3

  • Size and weight

    L (mm)

    4500

    W (mm)

    1870

    H (mm)

    2398

    Weight (Kg)

    5600

  • Engine

    Engine make and model

    VOLVO TWD1744GE

    Type of regulation

    Electronic

    Refrigeration

    Water-cooled

    Emissions

    EU Stage II

    Consumption 50%

    74,5 l/h

    Consumption 75%

    111,1 l/h

    Consumption 100% PRP

    147,4 l/h

    Consumption 100% ESP

    157,8 l/h

  • Alternator

    Alternator make and model

    MECCALTE ECO40 VL4 C

    Type of alternator regulation

    DER1

  • Circuit breaker

    Switch model

    Schneider ComPact 1250A 4P

    Amps ESP (A)

    1190,8

  • Control card

    Make and model

    DSE 7320 MKII

  • Downloadable documents
  • DGV 825 ME

    DGV 825 ME

    Range High Power

    | 50Hz

    Do you need an ATS for your installation?

    CONTACTORS TRANSFER SWITCHES

    Dagartech contactores

    Switching panels between mains and genset with Schneider Electric contactors and enclosure from the same manufacturer. With mechanical and electrical interlocking and switching management from the control panel. They have an optional mains failure detector.

    REMOTELY OPERATED MOTORISED TRANSFER SWITCH (RTS)

    Dagartech contactores

    Transfer switches with remote-operated 4-pole fully visible break. They allow in-load transfer of two three-phase sources via remote-voltage-free contacts, from an external automatic controller, using pulse logic or a switch.

    They are designed for use in low-voltage power systems where a brief interruption of load power during transfer is acceptable.

    Success Stories for this Range

    1,950 kVA Dagartech power to supply the Savoy Palace Hotel 5*

    1,950 kVA Dagartech power to supply the Savoy Palace Hotel 5*

    See case
    Dagartech secures power supply for one of the largest egg producers in Portugal

    Dagartech secures power supply for one of the largest egg producers in Portugal

    See case